Product operation method
5 seconds later, the following main interface is displayed:
Bootscreen
Synchronous self test ( self test dynamically displayed in the line
from left to right)
------
Lang:English
Cable Le ngt h
Scan Cab le
05
welcome
to choo se noya fa
NF-86 8
Wire mapping
There are nine functional options in the main menu interface
(1) LanguageEnglish or Chinese.
(2).Wire mapping --- Connection and disconnection test: to test connection
of M, S R end-end cable and perform positioning of the failure.
(3).Cable Length---Pairing and length measurement: verify cable length,
open circuit distance and pairing, crosstalk.
(4).Scan cable---to find target cable among lots of network cables,
telephone cables, USB cables, coaxial cables and other kinds of wires.
(5).Type--- Pair / Tel / USB / COAX / BNC Cable.
(6).Unit---Meter / Feet / Yards.
(7).CalibrateSeven calibration coefficient can be stored in it.
User can calibrate network/ telephone/ USB/ Coax cables.
(8) Data loading---Select the calibration coefficients stored in system.
(9) Auto power off— set the time for power off.
- - - - identify- - - -
Taking network test as an example: after entering connection test function,
press “ENTER” key to check wiremap. At this time, the following interface is
shown indicating test is in process:
a.Cable line-to-line test:
Test result 1: Short circuit
Sho rt map ping :
1 2 3 4 5 6 7 8
Cab le o pen or
too Short !
1 2 3 4 5 6 7 8 G
M:
R:
1 2 3 4 5 6 7 8 G
Wire Map: Remote
If there is short circuit with the cable and terminal, it will show as below:
(Short circuit with 3 and 6)
At this time, press any key to return to the main menu, and then press
“ENTER” key for re-test.
Please do not perform test again until short circuit problem solved.
Test result 2: if the far end of the cable to be tested is not plugged in
remote adapter (R) or cable is not plugged into the local port (S),
the following interface is shown:
Test result 3:correct connection
the following interface is shown:
Mstands for Master unit. “R” stands for remote unit.
Test result 4: In case of open circuit existing on far end of the cable,
the following interface is shown:
1 2 3 X X 6 7 8
M:
R:
1 2 3 X X 6 7 8
Wire Map: Remote
In the figure, Xshown in “4” and “5” pin position, indicates there is
open circuit in “4” and “5” pin of the remote pin.